Hoferichter C, Rüttermann S, Szep SG (2019) Influence of three different dentin bonding agents on the adhesion of composite resin to dentine–An in vitro study. J Dent Probl Solut 6(2): 056-060. DOI: 10.17352/2394-8418.000074The aim of this randomized in vitro study is to clarify if there are differences between the dentin adhesives as well as their adhesion and fracture behaviour. The study design was based on the ISO standard TS 11405 (2003). For this purpose, ninety extracted, caries-free human molars were embedded in a plastic block, and the dentinal surfaces were dissected free. Teeth were divided into three groups (n = 30) and each treated with a different adhesive system (SYC: Syntac Classic; CSE: Clearfil SE, CS3: Clearfil S3). All trial teeth were coated with a cylindrical standardized test specimen (diameter: 3.0 mm, height: 3.0 mm) on buccal surfaces with an ISOconforming application aid. The aging of the samples was achieved by thermocycling (500 cycles). Thereafter, the adhesive forces (MPa) of the various dentin adhesive systems were determined by means of shear bond testing with a universal testing machine from Zwick. The samples were examined under a scanning electron microscope at 20x and 2000x magnification for their fracture modes (adhesive, cohesive, mixed). Furthermore, parametric Weibull regression models were applied to evaluate whether there was a significant association between shear bond strength and the used adhesive system. Weibull analysis was performed using R software (version 2.11.1, R Foundation for Statistical Computing, Vienna, Austria). Differences between groups were tested using Wald tests, and p-values below 0.05 were considered significant.
CSE (3.97 MPa), followed by SYC (3.02 MPa), and CS3 (2.16 MPa) had the highest bond strength averages. The result of the statistical evaluation shows statistical differences between the different groups. Mostly mixed fractures were observed. SYC (m = 6.35) was most reliably followed by CSE (m = 4.75). The lowest Weibull module scored CS3 (m = 3.91).
Under the limitations of this study, it can be stated that the differences between the groups were significant and the One-Step Self-Etch-system (CS3) showed the lowest values. Additionally one major problem was the acrylic application aid (split mould according to ISO/TS 11405), which may have transferred adverse forces to the specimen and which cannot be recommended for further studies.
The demand for aesthetic, durable and quality restorations has increased significantly. Teeth should be unobtrusive and ideally minimally invasive reconstructed. It is a problem to get a permanent bond between the hydrophilic dentin and the hydrophobic composite [1,2]. Dentin adhesives play a key role in this [3-6]. In order to have feedback on the bond between composite materials and hard tooth substance, in vitro scientific studies are carried out. The experimental setups differ in many parameters in the studies and are therefore often not comparable. This variance variety influences the results [5]. Standardization of the parameters as in the ISO paper [4], is necessary to obtain comparable results. To our knowledge, no previous study has investigated the shear bond strength of the adhesive interface created by conventional Four-Step Etch-and Rinse and Self-etching Adhesives under the ISO/TS 11405 protocol.
The aim of this study was to compare three different dentin adhesives (control group: Four-Step Etch-and-Rinse versus experimental groups: Two-Step Self-etching and One-Step Self-etching) conforming to ISO (ISO TS11405: 2003) in terms of adhesive strength and fracture behaviour [5,6].
1. Is there a difference between the adhesion values obtained by the control group (Four-Step Etch-and-Rinse) on the one hand and the experimental groups on the other?
2. Are there differences between the fractures of the control group (Four-Step Etch-and-Rinse) and those of the experimental groups?
One hundred and twenty extracted human molars were completely embedded in a cold polymer (Technovit 4004, Kulzer, Hanau, Germany). All teeth were extracted for not longer than six months, were caries-free, unrestored and not root filled. After embedding, the numbering of the teeth was done to allow an exact assignment. Subsequently, the teeth were freed on the buccal surface except for the dentin. For this they were hand-worked on a polishing unit (Jean Wirz, Düsseldorf, Germany) with grinding wheels of different grain sizes (320-600 grit) at 6000 rpm with constant water cooling against overheating. The ISO standard TS11405 (2003) [4], requires a dentinal surface to be finished with a 600 grit abrasive paper. The teeth were rotated during the entire grinding process to achieve a uniformly ground surface. The plane parallelism was checked with a spirit level (Mercateo, Köthen, Germany). The samples were stored in distilled water at room temperature all the time until the experiment, which was changed every three days. The freedom from melting of the test surfaces was checked under a microscope (Wild Heerbrugg, Heerbrugg, Germany). It was also checked that there was no opening of the pulp and caries freedom. Teeth with these criteria were discarded. The number of teeth was reduced to ninety. These molars were randomized to three groups.
The ISO standard TS11405 (2003) [4], allows different test methods for measurement of bond strength. In this study, we chose shear bond testing. One sample each was clamped vertically into the universal testing machine (Zwick, Ulm, Germany). A shear blade moved at a constant speed (0.5 mm/min) toward the composite cylinder until the composite cylinder broke off from the dentin. Force transmitted to the load cell during the test was recorded by a computer and converted to voltage by the testXpert software (ZwickRoell, Ulm, Germany). A voltage drop of more than 30% was rated as a fraction of the sample and the maximum voltage measured so far registered as shear bond strength. The shear force was determined in Newton, which was converted to MPa for standardization. After the adhesion force measurement, the samples for the determination of the fracture type were evaluated by scanning electron microscopy (Hitachi, Tokyo) at 20-fold and 2000-fold magnification. The fracture types were differentiated into cohesive, adhesive and mixed fractures with cohesive fraction above or below 10%. Samples with a cohesive or mixed fraction exceeding 10% cohesive were not included in the statistical evaluation. Since only the other forms of fracture provide information about the bond [5].
For the statistical analysis of the results, the Kruskal-Wallis Multiple-Comparison Z-Value Test with a significance level of p ≤ 0.05 was applied. The test was performed using the statistical analysis package NCSS (Version 6.0.2.1. Kaysville, Utah). The strength values of the samples were evaluated by a Weibull distribution.
Weibull analysis was performed using R software (version 2.11.1, R Foundation for Statistical Computing, Vienna, Austria). Differences between groups were tested using Wald tests, and p-values below 0.05 were considered significant.
The individual results are shown in Tables 2-4. Most fractions are mixed forms with up to 80%. With the exception of CS3, there were otherwise more adhesive fractures (Table 2, Figures 2-4). CSE (3.97 MPa), followed by SYC (3.02 MPa), and CS3 (2.16 MPa) had the highest bond strength averages (Table 3). Significant differences were evaluated between SYC and CSE and between CSE and CS3 (Table 3). SYC (6.35) was most reliable followed by CSE (4.75). The lowest Weibull module scored ClS3 (3.91), (Table 4, Figure 5).
To date, no publications based on ISO TS 11405 2003 [4], have been published according to the investigated adhesives in our study. However, there exist many studies on the adhesive strength in the literature, and the dispersion of the results between different dentine adhesives is very large (Table 5). There are some studies that have achieved higher adhesive forces than our study [7-15], others reported from comparable [16-18], some also showed lower values (Table 5) [19-21]. These differences are mostly related to different study designs.
Since 2015 there exists a new revised specification of the ISO [22], which is unchanged in most points compared with the 2003 version. However, it seems be clear that it is not the absolute value of bond strengths that are decisive, but the relation between the investigated groups. As stated, it may be more appropriate to compare the ranking of materials [22]. It is also known, that while bond strength cannot predict exact clinical behaviour, they may be useful for batch quality control [4], or for comparing adhesive materials [22].
In some circumstances, bond strength tests are only useful for screening. They may allow only rough guidance with respect to the clinical performance of an adhesive system. Low values are more likely correlated with poor clinical performance namely retention in adhesive cavities. However, bond strength values above a certain threshold value might not indicate better clinical performance. This value is unfortunately not further clarified in the actual ISO version [22].
Many studies have found similar relations between the different types of adhesives as in the present study [8,10,13,15]. Cause of the differences may be the origin of teeth [23,24] bovine [8,13] or human even in human selection of areas [11,14,15]. It may cause differences in the preparation of the samples [11,14], whole teeth are embedded, the pulp chamber is blocked out [11-13,15], only toothed discs are used. An important point is also the influence of the application aids [10,12,16,17] and the choice of the aging process [14,18], for example only storage in water for days or months as well as thermocycling [8,10,15,17]. The methods of determining the adhesion [5,15,25,26] may differ even all in choice of the debonding speed [18,19,25]. In the review by Scherrer [5] 147 studies with six different adhesives were summarized. Depending on the test method used, the results of the 147 studies showed a very broad variation of the bond strength values, with the shear strength of the micro tensile strength test producing the higher adhesion values [5,15]. Many studies do not take into account the fracture modes [5,15-17], which are critical in determining shear bond strength and the inclusion of cohesive fractures may also influence the results. In the study by Makowski, a correlation was found between the occurrence of low adhesion values and adhesive fractures as well as high adhesion values and mixed fractures [11]. In that study, however, not the mixed fractions, as required by Scherrer, were subdivided again [5].
Most experimental values are not clinically relevant because they do not allow any information to the material reliability. Therefore, a Weibull analysis is strictly recommended [5,22], which was also calculated in our study. A major problem however was probably the recommended ISO application aid, which may have transferred adverse forces on the specimen (shear, bend or rotation). This split mould can be formed of polytetrafluoroethylene (PTFE) or other suitable materials, as stated in the ISO [5]. Our experiences with an acrylic mould material however cannot be recommended for further studies. Interestingly this split mould is no longer described in the actual ISO-version [22].
The differences between the groups were partly significant and the One-Step Self-Etch dentin adhesive system showed the lowest values. These were however not significantly different to the values of the Four-Step Etchand-Rinse adhesive. The Two-Step Self-Etching system has achieved the best results in both adhesion and reliability. Furthermore, the acrylic split mould according to ISO/TS 11405 cannot be recommended for further studies.